battery: read status with spaces

According to the [sysfs class power ABI],
/sys/class/power_supply/<supply_name>/status may contain "Not charging".
This is already handled by status_gt() and update() (where ' ' is
converted to '-' for use in config keys) but was not being read due to
skipws.  Read with std::getline() to handle this case.

[sysfs class power ABI]: https://www.kernel.org/doc/Documentation/ABI/testing/sysfs-class-power

Fixes: #1139
Signed-off-by: Kevin Locke <kevin@kevinlocke.name>
This commit is contained in:
Kevin Locke 2022-01-23 18:36:59 -07:00
parent d575646c2d
commit 27df7a9aa7
1 changed files with 1 additions and 1 deletions

View File

@ -161,7 +161,7 @@ const std::tuple<uint8_t, float, std::string, float> waybar::modules::Battery::g
uint32_t energy_now; uint32_t energy_now;
uint32_t energy_full_design; uint32_t energy_full_design;
std::string _status; std::string _status;
std::ifstream(bat / "status") >> _status; std::getline(std::ifstream(bat / "status"), _status);
// Some battery will report current and charge in μA/μAh. // Some battery will report current and charge in μA/μAh.
// Scale these by the voltage to get μW/μWh. // Scale these by the voltage to get μW/μWh.