battery: read status with spaces
According to the [sysfs class power ABI], /sys/class/power_supply/<supply_name>/status may contain "Not charging". This is already handled by status_gt() and update() (where ' ' is converted to '-' for use in config keys) but was not being read due to skipws. Read with std::getline() to handle this case. [sysfs class power ABI]: https://www.kernel.org/doc/Documentation/ABI/testing/sysfs-class-power Fixes: #1139 Signed-off-by: Kevin Locke <kevin@kevinlocke.name>
This commit is contained in:
parent
d575646c2d
commit
27df7a9aa7
|
@ -161,7 +161,7 @@ const std::tuple<uint8_t, float, std::string, float> waybar::modules::Battery::g
|
|||
uint32_t energy_now;
|
||||
uint32_t energy_full_design;
|
||||
std::string _status;
|
||||
std::ifstream(bat / "status") >> _status;
|
||||
std::getline(std::ifstream(bat / "status"), _status);
|
||||
|
||||
// Some battery will report current and charge in μA/μAh.
|
||||
// Scale these by the voltage to get μW/μWh.
|
||||
|
|
Loading…
Reference in New Issue