165 lines
4.6 KiB
Markdown
165 lines
4.6 KiB
Markdown
waybar-battery(5)
|
|
|
|
# NAME
|
|
|
|
waybar - battery module
|
|
|
|
# DESCRIPTION
|
|
|
|
The *battery* module displays the current capacity and state (eg. charging) of your battery.
|
|
|
|
# CONFIGURATION
|
|
|
|
*bat*: ++
|
|
typeof: string ++
|
|
The battery to monitor, as in /sys/class/power_supply/ instead of auto detect.
|
|
|
|
*adapter*: ++
|
|
typeof: string ++
|
|
The adapter to monitor, as in /sys/class/power_supply/ instead of auto detect.
|
|
|
|
*full-at*: ++
|
|
typeof: integer ++
|
|
Define the max percentage of the battery, for when you've set the battery to stop charging at a lower level to save it. For example, if you've set the battery to stop at 80% that will become the new 100%.
|
|
|
|
*design-capacity*: ++
|
|
typeof: bool ++
|
|
default: false ++
|
|
Option to use the battery design capacity instead of it's current maximal capacity.
|
|
|
|
*interval*: ++
|
|
typeof: integer ++
|
|
default: 60 ++
|
|
The interval in which the information gets polled.
|
|
|
|
*states*: ++
|
|
typeof: object ++
|
|
A number of battery states which get activated on certain capacity levels. See *waybar-states(5)*.
|
|
|
|
*format*: ++
|
|
typeof: string ++
|
|
default: {capacity}% ++
|
|
The format, how information should be displayed.
|
|
|
|
*format-time*: ++
|
|
typeof: string ++
|
|
default: {H} h {M} min ++
|
|
The format, how the time should be displayed.
|
|
|
|
*format-icons*: ++
|
|
typeof: array/object ++
|
|
Based on the current capacity, the corresponding icon gets selected. ++
|
|
The order is *low* to *high*. Or by the state if it is an object.
|
|
|
|
*max-length*: ++
|
|
typeof: integer++
|
|
The maximum length in character the module should display.
|
|
|
|
*min-length*: ++
|
|
typeof: integer ++
|
|
The minimum length in characters the module should take up.
|
|
|
|
*align*: ++
|
|
typeof: float ++
|
|
The alignment of the text, where 0 is left-aligned and 1 is right-aligned. If the module is rotated, it will follow the flow of the text.
|
|
|
|
*rotate*: ++
|
|
typeof: integer++
|
|
Positive value to rotate the text label.
|
|
|
|
*on-click*: ++
|
|
typeof: string ++
|
|
Command to execute when clicked on the module.
|
|
|
|
*on-click-middle*: ++
|
|
typeof: string ++
|
|
Command to execute when middle-clicked on the module using mousewheel.
|
|
|
|
*on-click-right*: ++
|
|
typeof: string ++
|
|
Command to execute when you right clicked on the module.
|
|
|
|
*on-update*: ++
|
|
typeof: string ++
|
|
Command to execute when the module is updated.
|
|
|
|
*on-scroll-up*: ++
|
|
typeof: string ++
|
|
Command to execute when scrolling up on the module.
|
|
|
|
*on-scroll-down*: ++
|
|
typeof: string ++
|
|
Command to execute when scrolling down on the module.
|
|
|
|
*smooth-scrolling-threshold*: ++
|
|
typeof: double ++
|
|
Threshold to be used when scrolling.
|
|
|
|
*tooltip*: ++
|
|
typeof: bool ++
|
|
default: true ++
|
|
Option to disable tooltip on hover.
|
|
|
|
# FORMAT REPLACEMENTS
|
|
|
|
*{capacity}*: Capacity in percentage
|
|
|
|
*{power}*: Power in watts
|
|
|
|
*{icon}*: Icon, as defined in *format-icons*.
|
|
|
|
*{time}*: Estimate of time until full or empty. Note that this is based on the power draw at the last refresh time, not an average.
|
|
|
|
# TIME FORMAT
|
|
|
|
The *battery* module allows you to define how time should be formatted via *format-time*.
|
|
|
|
The three arguments are:
|
|
*{H}*: Hours
|
|
*{M}*: Minutes
|
|
*{m}*: Zero-padded minutes
|
|
|
|
# CUSTOM FORMATS
|
|
|
|
The *battery* module allows one to define custom formats based on up to two factors. The best fitting format will be selected.
|
|
|
|
*format-<state>*: With *states*, a custom format can be set depending on the capacity of your battery.
|
|
|
|
*format-<status>*: With the status, a custom format can be set depending on the status in /sys/class/power_supply/<bat>/status (in lowercase).
|
|
|
|
*format-<status>-<state>*: You can also set a custom format depending on both values.
|
|
|
|
# STATES
|
|
|
|
- Every entry (*state*) consists of a *<name>* (typeof: *string*) and a *<value>* (typeof: *integer*).
|
|
- The state can be addressed as a CSS class in the *style.css*. The name of the CSS class is the *<name>* of the state. Each class gets activated when the current capacity is equal or below the configured *<value>*.
|
|
- Also each state can have its own *format*. Those con be configured via *format-<name>*. Or if you want to differentiate a bit more even as *format-<status>-<state>*. For more information see *custom-formats*.
|
|
|
|
|
|
|
|
# EXAMPLES
|
|
|
|
```
|
|
"battery": {
|
|
"bat": "BAT2",
|
|
"interval": 60,
|
|
"states": {
|
|
"warning": 30,
|
|
"critical": 15
|
|
},
|
|
"format": "{capacity}% {icon}",
|
|
"format-icons": ["", "", "", "", ""],
|
|
"max-length": 25
|
|
}
|
|
```
|
|
|
|
# STYLE
|
|
|
|
- *#battery*
|
|
- *#battery.<status>*
|
|
- *<status>* is the value of /sys/class/power_supply/<bat>/status in lowercase.
|
|
- *#battery.<state>*
|
|
- *<state>* can be defined in the *config*. For more information see *states*.
|
|
- *#battery.<status>.<state>*
|
|
- Combination of both *<status>* and *<state>*.
|