ServeControlStream accidentally became non-blocking in the last quic
change causing stream to not be returned until a SIGTERM was received.
This change makes ServeControlStream be non-blocking for QUIC streams.
This maximum grace period will be honored by Cloudflare edge such that
either side will close the connection after unregistration at most
by this time (3min as of this commit):
- If the connection is unused, it is already closed as soon as possible.
- If the connection is still used, it is closed on the cloudflared configured grace-period.
Even if cloudflared does not close the connection by the grace-period time,
the edge will do so.
time.Tick() does not get garbage collected because the channel
underneath never gets deleted and the underlying Ticker can never be
recovered by the garbage collector. We replace this with NewTicker() to
avoid this.
All header transformation code from h2mux has been consolidated in the connection package since it's used by both h2mux and http2 logic.
Exported headers used by proxying between edge and cloudflared so then can be shared by tunnel service on the edge.
Moved access-related headers to corresponding packages that have the code that sets/uses these headers.
Removed tunnel hostname tracking from h2mux since it wasn't used by anything. We will continue to set the tunnel hostname header from the edge for backward compatibilty, but it's no longer used by cloudflared.
Move bastion-related logic into carrier package, untangled dependencies between carrier, origin, and websocket packages.
added ingress.DefaultStreamHandler and a basic test for tcp stream proxy
moved websocket.Stream to ingress
cloudflared no longer picks tcpstream host from header
- extracted ResponseWriter from proxyConnection
- added bastion tests over websocket
- removed HTTPResp()
- added some docstrings
- Renamed some ingress clients as proxies
- renamed instances of client to proxy in connection and origin
- Stream no longer takes a context and logger.Service
- Don't rely on edge to close connection on graceful shutdown in h2mux, start muxer shutdown from cloudflared.
- Don't retry failed connections after graceful shutdown has started.
- After graceful shutdown channel is closed we stop waiting for retry timer and don't try to restart tunnel loop.
- Use readonly channel for graceful shutdown in functions that only consume the signal
Classic tunnels flow was triggering an event for RegisteringTunnel for
every connection that was about to be established, and then a Connected
event for every connection established.
However, the RegistreringTunnel event had no connection ID, always
causing it to unset/disconnect the 0th connection making the /ready
endpoint report incorrect numbers for classic tunnels.